LDE LASER TRIANGULATION SENSORS
LASER TRIANGULATION SENSORS
LDE SERIES
General information
The sensors are intended for non-contact measuring and checking of position, displacement, dimensions, surface profile, deformation, vibrations, sorting and sensing of technological objects as well as for measuring levels of liquid and bulk materials.
The series includes 12 sensors with the measurement range, from10 to 2500 mm and the base distance from 230 to 1 mm. The Series is divided into 3 groups. The first group includes the sensors with large bases and short measurement ranges, second group includes sensors with medium bases and ranges and the third group is the sen-sors with long ranges.
There are two options of laser mounted in the sensor, RED or BLUE laser. The use of blue lasers instead of conventional red lasers greatly enhances capabilities of the sensors, in particular, for such uses as control of high-temperature objects and organic materials. Custom-ordered configurations are possible with parameters different from those shown below.
■■ Large-base and long range laser sensors
■■ Measuring ranges from 10 to 2500 mm
■■ Linearity ±0.1%
■■ Resolution ±0.01%
■■ Sampling rate up to 9.4 kHz
■■ RS232/RS485/Ethernet/CAN +4...20 mA/0...10V
Basic technical data
LDE- |
X/10 |
X/30 |
X/40 |
X/100 |
X/250 |
X/500 |
X/600 |
X/1000 |
X/1000 |
X/1500 |
X/2000 |
X/2500 |
|||
Base distance X, мм |
230 |
300 |
330 |
500 |
230 |
300 |
230 |
1300 |
380 |
390 |
410 |
420 |
|||
Measurement range, mm |
10 |
30 |
40 |
100 |
250 |
500 |
600 |
1000 |
1000 |
1500 |
2000 |
2500 |
|||
Linearity, % |
±0.1 of the range |
±0.2 |
|||||||||||||
Resolution, % |
0.01 of the range (for the digital output only) |
0.03 |
|||||||||||||
Temperature drift |
0,02% of the range/0С |
||||||||||||||
Measurement frequency, Hz |
9400 |
||||||||||||||
Light source |
red semiconductor laser, 660 nm wavelength or UV semiconductor laser 405 nm wavelength (BLUE version) |
||||||||||||||
output power |
≤4,8 mW |
≤20 mW |
|||||||||||||
laser safety Class |
3R (IEC60825-1) |
3В (IEC60825-1) |
|||||||||||||
Output interface |
digital |
RS232 (max. 460,8 kbit/s) or RS485 (max. 921,6 kbit/s) or RS232 and CAN V2.0B (max 1Mbit/s) or Ethernet and (RS32 or RS485) |
|||||||||||||
analog |
4…20 mA (500 Ω load) or 0…10 V |
||||||||||||||
Synchronization input |
2,4 – 5 V (CMOS, TTL) |
||||||||||||||
Logic output |
programmed functions, NPN: 100 mA max; 40 V max for output |
||||||||||||||
Power supply, V |
9 …36 |
||||||||||||||
Power consumption, W |
1,5..2 |
||||||||||||||
Environment resistance |
Enclosure rating |
IP67 ( for the sensors with cable connector only) |
|||||||||||||
Vibration |
20g/10…1000Hz, 6 hours, for each of XYZ axes |
||||||||||||||
Shock |
30 g / 6 ms |
||||||||||||||
Operation temperature |
-10…+60° C, (-30…+60 for the sensors with in-built heater) |
||||||||||||||
Permissible ambient light |
lx 30000 |
||||||||||||||
Relative humidity |
5-95% (no condensation) |
||||||||||||||
Storage temperature |
20…+70 , °С |
||||||||||||||
Housing material |
Aluminum |
||||||||||||||
Weight (without cable) |
500g |
Products
Contattaci
Non esitate a contattarci, saremo lieti di soddisfare qualsiasi vostra richiesta di informazione di natura tecnica ed economica,relative alla nostra sensoristica.
Chiedi informazioni