SLP 2D LiDAR with best cost-performance ratio

SLP 2D LiDAR with best cost-performance ratio

 

SLP series

2D Laser Scanners for outdoor automation

► Long range up to 400 m

► 90° field of view

► High accuracy <5 mm

► Small spot size

► Fast pulse rate up to 60 kHz

► Tough and robust, IP67 certified

► Operating with rain and snow

► Multi-echoes evaluation technology with up to 4 echoes

► Low power consumption

► Real time Ethernet

Available in the following models: SLP100, SLP250, SLP300, SLP400

 

SLP scanners specifications 

  • Features

    SLP100

    SLP250

    SLP300

    SLP400

    Range (m) @ R=100%

    150

    250

    300

    400

    Range (m) @ R=10%

    45

    80

    95

    120

    Minimum range (m)

    0.8

    1.8

    2.5

    2.7

    Resolution (mm)

    1

    1

    1

    1

    Repeatability 1 σ1 (mm)

    5

    5

    5

    6

    Accuracy2 (mm)

    ≤ 5

    ≤ 5

    ≤ 5

    ≤ 5

    Divergence (°) p x II3

    0.041 x 0.029

    0.076 x 0.029

    0.096 x 0.029

    0.143 x 0.034

    Spot close to window (mm) p x II3

    12 x 18

    12 x 18

    12 x 18

    12 x 19

    Focusing distance4 (m)

    45

    Scan angle (°)

    up to 90

    Multi-echo evaluation

    up to 4

    Scan rate (Hz)

    selectable: 15 | 30 | 60

    Measurements in 90° (points)

    selectable: 2000 | 1000 | 500

    Laser type

    Pulse laser diode 905 nm

    Laser Eye Safety Class5

    1

    Pulse rate (kHz)

    60

    Interfaces

    Ethernet TCP/UDP 100 Mb/s
    RS232 selectable Bauds, 8n1 (for 1PPS only)
    Digital outputs 2 x 3.3 to 5 VDC programmable - Isolated switching outputs
    Digital inputs 2 x 3.3 to 5 VDC programmable - Isolated inputs
    External encoder inputs 3.3 to 5 VDC TTL input, channels A/B/Z

    Power supply

    24 VDC ± 5 VDC power supply

    Power consumption (W)

    12 (heater off) | 36 (heater on)

    Ingress Protection rating

    IP67

    Operating temperature

    -30°C to +50°C

    Storage temperature

    -30°C to +70°C

    Dimensions H x W x L (mm)

    247 x 121 x 109

    Weight (kg)

    2.8

1 strong signal

2 systematic error, residual after removing the statistical error 

3 p: perpendicular to scan direction II: parallel to scan direction

4 when focussed to shorter range, spot sizes are smaller

5 Laser Eye Safety Class; EN 60825-1; 94,96,01

Specifications are subject to change. All data without tolerances are typical values.