SLP HT 2D LiDAR for non-contact measurements on hot surfaces
SLP HT
2D LiDAR for non-contact measurements on hot surfaces
► Measurement on surface temperatures < 1100°C
► Optimal measurement distance on hot surfaces 7 to 10 m
► Maximum range on cold surfaces 150 m
► 90° field of view
► High accuracy <5 mm
► Small spot size
► Fast pulse rate up to 60 kHz
► Tough and robust, IP67 certified
► Multi-echoes evaluation technology with up to 4 echoes
► Low power consumption
► Real time Ethernet
SLP HT specifications
Features |
SLP HT |
---|---|
Range (m) @ R=100% |
150 |
Range (m) @ R=10% |
45 |
Optimal installation distance1 (m) |
from 7 to 10 |
Surface temperature range2 (°C) |
T ≤ 1100 |
Resolution (mm) |
1 |
Repeatability 1 σ3 (mm) |
8 |
Accuracy4 (mm) |
≤ 5 |
Divergence (°) p x II5 |
0.076 x 0.029 |
Spot close to window (mm) p x II5 |
12 x 18 |
Focusing distance6 (m) |
45 |
Scan angle (°) |
up to 90 |
Multi-echo evaluation |
up to 4 |
Scan rate (Hz) |
selectable: 15 | 30 | 60 |
Measurements in 90° (points) |
selectable: 2000 | 1000 | 500 |
Laser type |
Pulse laser diode 905 nm |
Laser Eye Safety Class7 |
1 |
Pulse rate (kHz) |
up to 60 |
Interfaces |
Ethernet TCP/UDP 100 Mb/s |
Power supply |
24 VDC ± 5 VDC power supply |
Power consumption (W) |
12 |
Ingress Protection rating |
IP67 |
Operating temperature |
-30°C to +50°C |
Storage temperature |
-30°C to +70°C |
Dimensions H x W x L (mm) |
247 x 121 x 109 |
Weight (kg) |
2.8 |
· 1 To reach the optimal performances in the measurements on hot surfaces, it is recommended to install the device at a distance between 7 meters and 10 meters from the target, with the laser beam hitting the target surface with the smallest incidence angle.
· 2 Thanks to the rough housing rated IP67, the SLP HT can operate in harsh environments in ambient temperatures of up to +50°C. In case the device needs to be installed in a warmer environment, a cooling system is recommended.
· 3 strong signal
· 4 systematic error, residual after removing the statistical error (Triple-IN procedure)
· 5 p: perpendicular to scan direction II: parallel to scan direction
· 6 when focussed to shorter range, spot sizes are smaller
· 7 Laser Eye Safety Class; EN 60825-1; 94,96,01
· Specifications are subject to change. All data without tolerances are typical values.
Products
Download
Contattaci
Non esitate a contattarci, saremo lieti di soddisfare qualsiasi vostra richiesta di informazione di natura tecnica ed economica,relative alla nostra sensoristica.
Chiedi informazioni